Well Pressure Tank Size Calculator: What Size Tank Do I Need?

Enter your well pump's flow and your pressure switch setting. You get the drawdown the tank must hold so the pump runs long enough each time, the tank size that gives it, and the air charge to set.

Inputs

GPM

The pump's rated flow at your pressure.

min
psi
psi

Your pressure tank

Updates as you type
34gallons

gallon tank or bigger (total volume) for 10 gallons of drawdown at 30/50 psi, so the pump runs at least 1 minute each time.

Pressure tank details
Usable share of the tank0.3
Air charge (tank empty)28 psi
Show the math
Drawdown needed: 10 GPM × 1 min = 10 galUsable share: 0.295Tank: 10 ÷ 0.295 = 33.9 gal

Estimate only. Check the drawdown on the tank's label and the minimum run time in your pump's manual.

The short answer

A 10 GPM well pump on a 30/50 pressure switch needs a pressure tank of at least 34 gallons total volume. The pump should run 1 minute or more each start, so the tank must deliver 10 gallons between starts, and only about 29.53% of a tank's volume comes out at 30/50 psi. Set the air charge to 28 psi.

Tank size by pump flow and switch setting

Smallest tank, total gallons, for a 1 minute minimum run time.

Pressure tank size by pump flow and pressure switch setting
Pump20/40 psi30/50 psi40/60 psi
5 GPM15 gal17 gal20 gal
7 GPM21 gal24 gal28 gal
10 GPM30 gal34 gal39 gal
12 GPM35 gal41 gal47 gal
15 GPM44 gal51 gal59 gal
20 GPM59 gal68 gal78 gal
25 GPM73 gal85 gal97 gal

How it works

The formula

The tank has to give the pump something to fill: at least its flow times the minimum run time. A diaphragm tank only delivers part of its volume, set by how far the air inside compresses between the two switch pressures (Boyle's law).

drawdown = pump GPM × minimum run time
usable share = (air charge + 14.7) × (1 ÷ (cut-in + 14.7) − 1 ÷ (cut-out + 14.7))
tank = drawdown ÷ usable share

Assumptions

  • The formula and the 1 minute minimum run time follow Pentair's WellMate pressure tank sizing guide. Our usable shares match its drawdown chart: 20/40 psi 0.34, 30/50 0.3, 40/60 0.26.
  • The air charge is 2 psi below cut-in, the usual setting; 14.7 psi turns gauge pressure into absolute.
  • The tank size is total volume; tank labels also list the drawdown at each setting, which you can compare with the drawdown here.

Worked example: 10 GPM pump, 30/50 switch

  1. Drawdown: 10 GPM × 1 min = 10 gal
  2. Usable share: (28 + 14.7) × (1 ÷ 44.7 − 1 ÷ 64.7) = 0.295
  3. 10 ÷ 0.295 = 33.9 → at least 34 gallons

Too big or too small

  • Too small: short cycling. The pump starts every few seconds of water use, wearing out the motor, the switch and the check valves.
  • Waterlogged tank: same as too small. If the air charge is gone, the tank holds little water; check it once a year with the pump off.
  • Raise the switch, raise the tank. At 40/60 a tank delivers less of its volume than at 30/50, so it has to be bigger.

Questions people ask

What size pressure tank do I need for a 10 GPM pump?

At least 34 gallons of total tank volume on a 30/50 switch. The pump should run at least 1 minute each start, so the tank must hold 10 gallons of drawdown, and at 30/50 only about 29.53% of a tank's volume comes out between pump starts. On a 40/60 switch it's 39 gallons.

What is drawdown?

The water a pressure tank delivers between the pump shutting off and turning back on. It is only part of the tank: the rest is the compressed air that pushes the water out. Tank labels list drawdown at 20/40, 30/50 and 40/60 psi.

What should the air pressure in my tank be?

2 psi below the pump's cut-in pressure, checked with the pump off and the tank empty: 28 psi for a 30/50 switch, 38 psi for 40/60.

Is a bigger pressure tank better?

For the pump, yes: fewer, longer runs mean less wear and heat in the motor. A bigger tank also stores more water during a power outage. The limits are space, cost and the floor load of a full tank.

Why does the minimum run time matter?

A well pump motor heats up at every start and needs time running to cool and to carry the heat away. Pentair's WellMate guide asks for at least 1 minute; check your pump's manual, as some larger motors need more.